Including VAT
Hot air boiler VIGAS 25 TVZ
Technical description
The hot air boiler VIGAS TVZ is designed for burning dry firewood from sawdust to logs up to 35 cm long. Sawdust, shavings, shavings and trimmings should be burned together with larger logs. The contents of the hopper are sufficient for 6-10 hours of normal boiler operation.
The boiler is welded from 4 and 6 mm thick steel sheets. The inner body of the boiler, which comes into contact with flue gases, is made of sheet metal with a thickness of 6 mm and treated with an anti-corrosion spray. The heat exchanger is welded steel pipes Ø57×4.5 mm.
The combustion chamber space is lined with 20 mm thick fireclay bricks. The cover casing is made of sheet metal with a thickness of 0.8 mm. The boiler insulation consists of NOBASIL material, the thickness of which is 20 and 40 mm.
Control
The electronic control AK 4000 is a new control unit for VIGAS boilers. It meets the requirements of simple operation. Already in the basic version, it is possible to connect a room temperature controller or an exhaust fan. It allows you to regulate the time and temperature of the boiler with a weekly program. It indicates fuel burnout, fuel control or malfunctions with its description. During the process of fuel gasification and combustion, the AK 4000 electronic control monitors temperature changes and, if necessary, smoothly increases or decreases the fan speed.
Application
The main area of use of hot air heating is industrial buildings (halls) and drying rooms.
Advantages
The advantage of warm air heating is excellent operational readiness and heating can be easily combined with ventilation.
Basic equipment:
AK 4000 regulation
EBM pressure fan
Cooling fan
Flue gas thermometer, type PT1000
Aerated concrete nozzle LAC
Thermal fuse
Cleaning accessories
Technical data
Nominal boiler output kW 25
Fuel wood
Power range kW 5-28
Hot air flow m3/hour 950
Fuel consumption min. performance kg/hour 6.9
Efficiency % 85
Backup fuel Wood waste, chips, sawdust, sawdust briquettes
Chimney draft mBar 0.15-0.20
Exhaust air temperature setting range °C 40-120
Boiler weight kg 450
Adjustable height Un mm 1250.
Outlet height B mm 1540.
Suction neck height C mm 330
Chimney neck height D mm 1000
Width including rod E mm 645
Width with cladding F mm 590
Depth G mm 1280
Exhaust nozzle H mm 240
Outlet size mm 250 × 250
Exhaust pipe diameter Es mm 159
Filling chamber size - Depth mm 490
Height mm 500
Width mm 440
Filling opening dimensions (w × h) mm 435 × 255
Max. fuel weight kg 28
Filling chamber volume l 110
Noise dB 70.5
Electrical input W 640
Burning time min. performance hours 3.80
Flue mass flow kg/s 0.034-0.047
Voltage/frequency ~V/Hz 230/50